RT-130 Decorative banner. Group of photos depicting wildland firefighters performing various duties.

1994 South Canyon Fire on Storm King Mountain

This module looks at the South Canyon Fire where 14 perished, and discusses safety, hazards, risk, and entrapment avoidance.
Category: Case Studies
Core Component(s):
Incident Reviews and Lessons Learned, Fire and Aviation Operational Safety, Human Factors, Communication and Decision Making, Fire Shelters and Entrapment Avoidance
Estimated Delivery Time: 2 hour
Video Length: Part 1: 39:50; Part 2: 41:52

Part 1

Part 2

 

Intent

Review the sequence of events that led to tragedy on the South Canyon Fire and discuss significant lessons learned.

Facilitator Preparation

  • Review the two videos and module tools.
  • Consider additional activities and discussion questions pertinent to the location and agency.

Facilitating the Discussion

  • Show the two videos.
  • Facilitate a small or large group discussion using the activity and discussion questions below.
  • Guide discussion based on the Downhill Checklist in the Incident Response Pocket Guide (IRPG), PMS 461. Provide copies of the IRPG for students to utilize and answer questions.

Discussion Questions

Part 1

  1. Which hazardous conditions for downhill fireline construction were present?
  2. What supervisory/overhead personnel and crew supervisors discussed the situation prior to committing crews to the assignment?
  3. What supervisory/overhead personnel stayed with the job?
  4. Was the fireline scouted?  When was the decision made to engage the fire?
  5. Was there direct contact between the crew(s) and a lookout(s) that could see the fire?
  6. Was there communication between all personnel from top to bottom?
  7. Was there rapid access to a pre-identified identified safety zone?
  8. Was direct attack being used?
  9. Was the fireline in or adjacent to a chute or chimney?
  10. Was the fireline anchored at the starting point on top?
  11. Was the bottom of the fire being monitored?
  12. What other tactical alternatives could have been used on this fire?

Part 2

  • Consider the casual factors identified in Part 1; then summarize the significant lessons to be learned from this case study.

Resources

Additional Video Information

  • These videos are also available as a download (Part 1) (zip file, size 8 GB)​ and  download (Part 2) (zip file, size 8 GB)​ with .srt files for closed captioning (you may need to right click and Save As). For information on how to add closed captioning to a video, see this how to page.
  • Note: For Chrome, Firefox, and Edge, right click the word download and select Save Link As; for Internet Explorer (IE), right click and select Save Target As.

Last Modified / Reviewed:

Please Provide Feedback

NWCG values your constructive input and we thank you for taking the time to provide feedback.

Although contact information is optional, we hope that you provide a way for us to contact you in case we need clarification on your comment. If you would like to be contacted regarding your feedback, you must provide contact information. 

Would you like a response?
If you would like a response, you must provide contact information (name and email) below.
One file only.
9.28 GB limit.
Allowed types: gif, jpg, jpeg, png, bmp, eps, tif, pict, psd, txt, rtf, html, odf, pdf, doc, docx, ppt, pptx, xls, xlsx, xml, avi, mov, mp3, mp4, ogg, wav, bz2, dmg, gz, jar, rar, sit, svg, tar, zip.

NWCG Latest Announcements

Updated NWCG Standards for Water Scooping Operations, PMS 518

Date: December 19, 2024
Contact: Water Scooper Operations Unit

The NWCG Standards for Water Scooping Operations, PMS 518 establishes the standards for dispatching, utilizing, and coordinating water scooping aircraft on interagency wildland fires. These standards should be used in conjunction with the NWCG Standards for Aerial Supervision (SAS), PMS 505, and any local, state, or geographic/regional water scooping plans.

References:

NWCG Standards for Water Scooping Operations, PMS 518

Updated NWCG Standards for Aerial Supervision, PMS 505

Date: December 19, 2024
Contact: Interagency Aerial Supervision Subcommittee

The Interagency Aerial Supervision Subcommittee has updated the NWCG Standards for Aerial Supervision, PMS 505. PMS 505 establishes standards for aerial supervision operations for national interagency wildland fire operations. 

References:

NWCG Standards for Aerial Supervision, PMS 505

New Job Aids Available: Packing Lists for Wildland Fire Fireline Personnel and Support Staff, J-101 and J-102

Date: December 3, 2024
Contact: NWCG TRAINING

Two new job aids are now available: Packing List for Wildland Fire Fireline Personnel, J-101 and Packing List for Wildland Fire Support Personnel, J-102, should serve as a baseline for items needed on a wildland fire assignment. These lists will help personnel prepare for a 14 to 21-day assignment on the fireline or in a support role.

References:

Job Aid Catalog

NWCG Packing List for Wildland Fire Fireline Personnel, J-101

NWCG Packing List for Wildland Fire Support Staff, J-102

NWCG Equipment Technology Committee Releases Safety Warning: 24-001 Stihl Chainsaw Toolless Fuel Cap Spill Prevention

Date: November 14, 2024
Contact: Equipment Technology Committee

The Equipment Technology Committee (ETC) has released Safety Warning: 24-001 Stihl Chainsaw Toolless Fuel Cap Spill Prevention. Misaligned toolless fuel caps on Stihl chainsaws have led to recurring fuel spillage, fuel ignition, and burn injuries during wildland fire management operations.

This Safety Warning is intended to highlight the details and recommended procedures for the installation of a Stihl chainsaw toolless fuel cap, as well as how to identify and correct a misaligned, damaged, or broken fuel cap to help prevent fuel spillage.

References:

NWCG Safety Warning: 24-001 Stihl Chainsaw Toolless Fuel Cap Spill Prevention

Advertencia de equipos 24-001: Prevención de derrames de la tapa de combustible sin herramientas de la motosierra Stihl

NWCG Alerts









ApplySandwichStrip

pFad - (p)hone/(F)rame/(a)nonymizer/(d)eclutterfier!      Saves Data!


--- a PPN by Garber Painting Akron. With Image Size Reduction included!

Fetched URL: http://www.nwcg.gov/training-courses/rt-130/case-studies/cs201

Alternative Proxies:

Alternative Proxy

pFad Proxy

pFad v3 Proxy

pFad v4 Proxy