Content-Length: 86900 | pFad | https://2010-2014.commerce.gov/blog/2015/03/23/../../../2014/../2009/../2012/../category/3131.html

FW Blog Category: MRI | Department of Commerce
THIS IS AN ARCHIVED SITE
This site contains information from January 2009-December 2014. Click HERE to go the CURRENT commerce.gov website.

Blog Category: MRI

NIST’s MRI Measurement Tools to Help Diagnose Veterans’ Traumatic Brain Injuries

Brain wiring diagram made by high-definition fiber tracking magnetic resonance imaging (HDFT MRI) of water diffusion. The technique is useful for studies of traumatic brain injury.

More than 300,000 U.S. veterans have been diagnosed with traumatic brain injury (TBI) in recent years, a legacy of the Iraq and Afghanistan wars. But these numbers don’t tell the whole story. While severe TBI can be obvious, milder cases involving symptoms such as memory loss or inability to concentrate are difficult to confirm and treat.

Advanced imaging of the microscopic motion of water molecules in the brain shows promise for detecting these subtle injuries. A new study of TBI using this diffusion magnetic resonance imaging (MRI) technique will get a quality control boost from the National Institute of Standards and Technology (NIST), which has been working in collaboration with other organizations for nearly a decade to improve quantitative measures for MRI.*

NIST has developed a series of MRI “phantoms” to enable measurements that can be traced to international standards.** Phantoms are stable reference objects designed to mimic human tissue responses to MRI, but in a predictable, repeatable way. They are used to calibrate MRI scanners.

As interest in quantitative MRI measurements grows, NIST phantoms are being tested around the world, used in U.S. clinical trials, and transferred to industry. The goal is to improve image comparisons across scanners, test sites and time, thereby enhancing quality of care and reducing medical costs. NIST has applied for a patent on its basic phantom design and use to help promote commercialization.***

NIST and collaborators have already developed a phantom for diffusion MRI, which is now being tested in Europe and the United States. “It has shown very good reproducibility so far,” NIST’s Michael Boss says. “Diffusion MRI can reveal differences between tumors and normal tissue. But until now, there has been no widely accepted phantom or traceability to standards. NIST’s expertise lies in phantom development and what characteristics they should have in order to determine sources of error and inform protocols to be used with MRI patients.”

A new quantitative MRI study, co-led by researchers from NIST and three other institutions, will look for evidence of brain injury in patients with suspected TBI. The two-year study is part of a Department of Veterans Affairs (VA) effort to reliably diagnose TBI and predict outcomes and care needs. The study requires the creation of a new, head-sized MRI phantom to measureanisotropic diffusion, which tracks water molecules as they move in specific directions through the brain. Their motions can reveal structural information such as abnormalities in neural pathways. Nerve cell damage is believed to be a driving factor in TBI. Diffusion imaging has revealed changes in brain structure in some people with mild TBI; researchers say it has great potential to characterize and quantify the integrity of brain tissue.









ApplySandwichStrip

pFad - (p)hone/(F)rame/(a)nonymizer/(d)eclutterfier!      Saves Data!


--- a PPN by Garber Painting Akron. With Image Size Reduction included!

Fetched URL: https://2010-2014.commerce.gov/blog/2015/03/23/../../../2014/../2009/../2012/../category/3131.html

Alternative Proxies:

Alternative Proxy

pFad Proxy

pFad v3 Proxy

pFad v4 Proxy