code_name |
Measure method
|
units |
WOD code
|
201 |
Titration (Knudsen 1902)
|
203 |
UNESCO (Cox et al. |
204 |
Fofonoff et al. (1974)
|
205 |
Perkin and Walker (1972)
|
206 |
Bennett (1976)
|
207 |
Ribe and Howe (1975)
|
208 |
Federov (1971)
|
209 |
Other salinity methods
|
300 |
Winkler method (unknown)
|
301 |
Winkler automated oxygen titration; whole bottle method (Carpenter 1965)
|
302 |
Winkler method (Radiometer automated titrator)
|
303 |
Winkler automated oxygen titration: amperometric end-detection (Culberson 1991)
|
304 |
Winkler automated oxygen titration: photometric end-detection
|
305 |
Winkler manual oxygen titration: visual end-point (Strickland and Parsons 1972)
|
306 |
Winkler manual oxygen titration: visual end-point (Carpenter 1965 |
307 |
Winkler automated oxygen titration; whole bottle method & photometric end-detection (Jones 1992; Levy et al. 1977)
|
308 |
Winkler manual oxygen titration: visual end-point
|
321 |
Beckman polarographic oxygen sensor (CTD)
|
322 |
Beckman polarographic oxygen sensor (Owens and Millard 1985)
|
323 |
SBE 43 Dissolved Oxygen Sensor; Clark polarographic membrane
|
340 |
Chromatography
|
360 |
Spectrophotometric (Shibala method)
|
4100 |
Winkler automated oxygen titration; (Williams and Jenkinson 1982; Friederich et al. 1991)
|
4101 |
Winkler automated oxygen titration; whole bottle method; end-detection
|
400 |
Spectrophotometric
|
401 |
Spectrophotometric single solution method (Strickland and Parsons 1972)
|
402 |
Spectrophotometric stannous chloride reduction
|
403 |
Spectrophotometric persulphate oxidation (Menzel and Corwin 1965)
|
404 |
Spectrophotometric perchloric acid digestion)
|
405 |
Spectrophotometric reduced beta silico-molybdate (Strickland and Parsons 1972)
|
406 |
Spectrophotometric reduced alpha silico-molybdate (Grasshof 1964)
|
407 |
Cadmium reduction (Morris and Riley 1963; Wood et al. 1967)
|
408 |
Strychnidine method (Rochford 1947)
|
409 |
Spectrophotometric phenolhypochlorite method (Solorzano 1969)
|
410 |
Spectrophotometric (Richards and Thompson 1952)
|
411 |
Spectrophotometric (SCOR/UNESCO 1966)
|
412 |
Spectrophotometric (Parsons and Strickland 1963)
|
413 |
Spectrophotometric (Jeffrey and Humphery 1975)
|
500 |
Autoanalyzer |
501 |
Technicon Autoanalyzer model unknown (Murphy and Riley 1962)
|
502 |
Continuous flow autoanalyzer (CFA) colorimetric
|
503 |
Continuous Flow Analyzer (Bendschneider and Robinson 1952)
|
504 |
Continuous Flow Analyzer (CFA) Indophenol blue (Berthelot's reaction)
|
505 |
Nitrate+Nitrite - autoanalyzer
|
506 |
A Modification of colorimetric determination of silicic acid (Alimarin and Zverev |
507 |
Continuous flow autoanalyzer (CFA) (Alpkem)
|
508 |
Continuous flow autoanalyzer (CFA) (Skalar instrument)
|
509 |
Silicic acid concentration in water (Dienert and Wandenbulcke |
510 |
Ammonium samples were analyzed according to Lachat Instrument QuikChem method 31-107-06-1-B.
|
511 |
Phosphates are determined by Lachat Instrument QuikChem Method 31-115-01-1-H.
|
512 |
Silicates were measured using Lachat Instrument Method 31-114-27-1-C.
|
513 |
Nitrates and Nitrites were determined using Lachat Instrument Method 31-107-04-1-C.
|
600 |
Fluoroscence
|
601 |
Fluoroscence in situ Turner fluorometer (Strickland and Parsons 1972)
|
602 |
Fluoroscence in vivo underway (Lorenzen 1966)
|
603 |
Fluorometer in-situ CTD
|
604 |
Fluorometer (Aiken 1981)
|
605 |
Fluorometric chl-a assay acetone extraction
|
606 |
Fluorometric chl-a assay methanol extraction
|
607 |
Fluorometric chl-a assay acetone extraction; Turner fluorometer (Yentsch and Menzel |
608 |
Chlorophyll and phaeopigments are measured fluorometrically using an acidification technique which may include chlorophyll-b interference (Holm-Hansen and Riemann |
609 |
Chlorophyll-a values based on the Welschmeyer method which corrects for chlorophyll-b and phaeophytin interference (Welschmeyer |
700 |
HPLC (High Performance Liquid Chromatography)
|
701 |
HPLC (normal phase High Performance Liquid Chromatography)
|
702 |
HPLC (reverse phase High Performance Liquid Chromatography)
|
800 |
14C in-situ incubation
|
801 |
Carbon-14 (14C) simulated in-situ or deck incubation
|
802 |
Carbon-14 (14C) artificial light incubation
|
803 |
Sorokin's method
|
804 |
artificial light incubation (Hawaii method)
|
805 |
artificial light incubation (Australian method)
|
806 |
in situ light incubation (Hawaii method)
|
807 |
in situ light incubation (Australian method)
|
808 |
Carbon-14 (14C) simulated in-situ or deck incubation (Steeman Nielsen 1952; Doty and Oguri 1958)
|
860 |
Van Dorn (Japanese)
|
900 |
Automated titration
|
901 |
Modified Gran titration (Brewer et al. 1986)
|
910 |
Ruppin's method (Zubov 1937)
|
920 |
Coulometric (Johnson et al. 1985)
|
921 |
Coulometric Single operator multi-param metabolic analyzer (SOMMA)
|
922 |
Coulometric; Single Operator Multi-Metabolic Analyzer (SOMMA) [Johnson et al. |
923 |
Coulometric (Johnson et al. 1993b)
|
924 |
Potentiometric titration (Mintrop et al. |
942 |
Spectroscopic pH (25 degrees Celcius) and coulometric TCO2 using the carbonic acid dissociation constants of Mehrbach et al. (1973) as refit by Dickson and Millero (1987)
|
1000 |
C/N analyzer - GF/F filter
|
1001 |
BATS GF/F (0.7 um) CEC Elemental Analyzer
|
1002 |
BOFS 200pm pre-filter then GF/F Europa Roboprep Analyzera
|
1003 |
CEAREX: GF/F; Perkin Elmer Model 240B Elemental Analyzer
|
1004 |
KH754: Type C GF/F; Yanagimoto CHN Analyzer
|
1050 |
Spectrophotometric wet oxidation with dichromate (Strickland and Parsons 1972)
|
1100 |
High Temperature Catalytic Oxidation (HTCO) (Sugimura and Suzuki)
|
1101 |
Ultraviolet (UV) oxidation
|
1102 |
Wet oxidation (ie. persulphate)
|
1103 |
High Temperature Catalytic Oxidation (HTCO) ionics catalytic oxidation with IR CO2 detection
|
1104 |
High Temperature Catalytic Oxidation (HTCO) Shimadzu catalytic oxidation with IR CO2 detection
|
1200 |
Gas chromatography
|
1201 |
Gas chromatography (Weiss 1981)
|
1202 |
Gas chromatography xCO2 at analysis temperature
|
1203 |
Gas chromatography (Bulsiewicz et al. |
1205 |
Gas chromatography pCO2 at analysis temperature
|
1231 |
Infrared spectrometry
|
1233 |
Infrared spectrometry pCO2
|
1261 |
Nondispersive Infrared spectrometry (NDIR)
|
1262 |
Nondispersive Infrared spectrometry (NDIR) xCO2 at analysis temperature
|
1300 |
pH meter (potentiometric)
|
1340 |
Coulometric
|
1343 |
Coulometric (manual operation)
|
1344 |
Coulometric; automated operation; single-operator multiparameter metabolic analyzer (SOMMA)
|
1450 |
pH; spectrophotometry
|
1460 |
pH value determined manually using a pH color chart (Buch 1937)
|
1461 |
pH scale SWS25 ! do not use as method. Use scale header 3
|
1462 |
pH scale NBS25 ! do not use as method. Use scale header 3
|
1463 |
pH determined spectrophotometrically using the indicator m-cresol purple following Tupas et al. (1993) [Hawaii Time Series].
|
1464 |
Total (titration) alkalinity determined using the modified Gran titration method as described in Tupas et al. (1997) [Hawaii Time Series]..
|
4001 |
Freon gas extraction (Bullister and Weiss 1988)
|
4054 |
Winkler automated oxygen titration: whole-bottle method; photometric end-detection (Culberson 1991)
|
4056 |
Winkler automated oxygen titration: amperometric end-detection (Knapp et al. 1989)
|
4057 |
Winkler automated oxygen titration: amperometric end-detection
|
4058 |
Winkler automated oxygen titration: potentiometric and photometric end-detection (Culberson 1991; Culberson et al. 1991; Dickson 1994)
|
4059 |
Winkler automated oxygen titration: whole-bottle method; photometric end-detection (Culberson 1992; Carpenter 1969; Friederich et al. 1991)
|
4061 |
Winkler automated oxygen titration: whole-bottle method; amperometric end-detection (Culberson and Huang 1987)
|
4062 |
Gran-linearized potentiometric Winkler titration (Anderson et al. |
4063 |
Continuous Flow Analyzer (CFA) (Gordon et al. 1993)
|
4064 |
Modified gran approach (Dickson et al. |
4065 |
Alkalinity method of Perez and Fraga (1987)
|
4102 |
Winkler automated oxygen titration (Rosenberg et al. 1995)
|
4103 |
Continuous Flow Analyzer (CFA); Technicon Autoanalyzer model unknown (Armstrong et al. 1967)
|
4104 |
Continuous Flow Analyzer (CFA); Technicon Autoanalyzer model unknown (Bernhardt and Wilhelms 1967)
|
4105 |
Continuous Flow Analyzer (CFA); Technicon Autoanalyzer model unknown (Friedrich and Whitledge |
4106 |
Continuous Flow Analyzer (CFA); Murphy and Riley (1962)
|
4107 |
Continuous Flow Analyzer (CFA); Raimbault et al. (1990)
|
4108 |
Continuous Flow Analyzer (CFA); Fanning and Pilson (1973)
|
4109 |
Fluoroscence in vivo underway (Kerouel and Aminot 1997)
|
4110 |
Dissolved inorganic nutrients (Armstrong |
4111 |
Dissolved inorganic nutrients (Grasshoff |
4112 |
Dissolved inorganic nutrients (Strickland and Parsons |
4113 |
Winkler manual oxygen titration: visual end-point (Strickland and Parsons |
4114 |
Winkler manual oxygen titration: visual end-point |
4115 |
Manual volumetric titration
|
4116 |
Spectrophometric following method of Robinson and Thompson (1948)
|
4117 |
Continuous Flow Analyzer (CFA); Kirkwood (1995)
|
4118 |
Salinity computed from Chlorinity data (Tcyrikova and Shylgina |
4119 |
Dissolved inorganic nutrients (Whitledge et al. |
4120 |
Salinity computed from Chlorinity data calculated from conductivity (Schiemer and Pritchard |
4121 |
pCO2/fCO2 measurement taken at 4 degrees celcius
|
4122 |
pCO2/fCO2 measurement taken at 20 degrees celcius
|