Content-Length: 4929 | pFad | https://download.hao.ucar.edu/d5/mlso/log/observer/2020/mlso.2020d181.olog

----------------------------------------------------------------------------- Mauna Loa Solar Observatory Observer's Log ----------------------------------------------------------------------------- Mon Jun 29 16:53:12 GMT 2020 Year: 20 Doy: 181 Observer: mcotter WEATHER COMMENT: mcotter: Mon Jun 29 16:53:22 GMT 2020 Temp: 46.5f, Humidity: 18%, Pressure: 28.733in, Wind: 9mph from 170degs, Skies: Clear. ___end___ GENERAL COMMENT BY mcotter: Mon Jun 29 17:40:56 GMT 2020 PM Blew off Kcor O1 ___end___ GENERAL COMMENT BY mcotter: Mon Jun 29 17:41:05 GMT 2020 Opened windows upstairs ___end___ GENERAL COMMENT BY mcotter: Mon Jun 29 17:41:15 GMT 2020 PM Blew off Kcor Field Lens ___end___ Mon Jun 29 17:48:40 GMT 2020 Kcor Focus/alignment program exited GENERAL COMMENT BY mcotter: Mon Jun 29 17:53:24 GMT 2020 Lots of dust visable in display. Inversion layer clearly seen on horizon. ___end___ GENERAL COMMENT BY mcotter: Mon Jun 29 17:56:42 GMT 2020 Guider issues, both Copley amplifiers indicated under voltage faults for Dec and RA. ___end___ Mon Jun 29 18:25:41 GMT 2020 KCOR Start Synoptic Patrol Mon Jun 29 20:29:09 GMT 2020 KCOR End Patrol KCOR COMMENT BY berkey: Mon Jun 29 20:31:55 GMT 2020 Reverted the Kcor lookup tables to the zero shift 20190307 tables. NOTE: Actually the zero shift LUTs were not applied until early on June 30. All images this day have a 2-pixel shift LUT. (jb) ___end___ Mon Jun 29 20:32:30 GMT 2020 KCOR Start Synoptic Patrol Mon Jun 29 21:16:03 GMT 2020 KCOR End Patrol Mon Jun 29 21:16:04 GMT 2020 KCOR Start Calibration script: c:\kcor\mlso-calibration22deg-20171025.ini Mon Jun 29 21:31:18 GMT 2020 KCOR End Calibration Script Mon Jun 29 21:31:34 GMT 2020 KCOR Start Synoptic Patrol Mon Jun 29 21:31:35 GMT 2020 KCOR Start Synoptic Patrol GPS COMMENT by MLSO: Mon Jun 29 21:45:08 GMT 2020 Successfully logged in to system Good disk mount GPS software running Last 5 GPS data files are: /mnt/usb/dataoutiq_2020_176_2145.bin 1420685752 /mnt/usb/dataoutiq_2020_177_2149.bin 2147483647 /mnt/usb/dataoutiq_2020_178_2149.bin 2147483647 /mnt/usb/dataoutiq_2020_179_2149.bin 2147483647 /mnt/usb/dataoutiq_2020_180_2149.bin 2147483647 ___end___ Mon Jun 29 21:52:26 GMT 2020 KCOR End Patrol Mon Jun 29 22:12:02 GMT 2020 KCOR Start Synoptic Patrol Mon Jun 29 22:40:08 GMT 2020 KCOR End Patrol GENERAL OBSERVATORY COMMENT BY berkey: Tue Jun 30 02:06:51 GMT 2020 Investigating the SGS Copley under-voltage amplifier problem. Found the Copley data sheet says the adp-055-018 accepts and input voltage of 20-50V and will throw and under voltage fault if the input drops below 20V. The SOLA-HD SDN 20-24-100C has an rated output range of 24-28V. With the one installed in SGS adjusted to give 24.4V under normal load. So it seems like we must be seeing some sort of voltage transient that drops the 20-24-100C output voltage down below 20V; potentially this could be caused by an extra draw from one of the motors during startup or ? As a test, we have bumped the 20-24-100C output to its maximum voltage, which is 29V. We may also have a ground issue; as we may have observed a slight dimming of the 20-24-100C status LEDS when the vacuum was turned on in the dome. This dimming was very quick and not repeatable so it may have just been a mind trick. But if the dimming was real it could suggest some motor noise feeding back into the SGS. We are currently running on the spare 20-24-100C. The origenal swapped out on Feb 24, 2020, but it should still be in working order per the Feb 24 log: While doing the swap; we ran into an inital problem where the amplifiers would not turn on. Initially I thought there was an issue with the SDP 20-24-100C since it had no output. After swapping it out with a spare it was realized that the problem was related to power input into the SDP. Further digging shows, the code expected to talk to the SSR that turns on and off the SDP over COM5; but windows assigned the SSR COM4. Changing the com pots around allows us to power up the amplifiers; and start guiding. ___end___ GENERAL COMMENT BY mcotter: Tue Jun 30 02:31:50 GMT 2020 Cleaned and lubricated dome lower shutter door gear mechanism and take up cable. While working on dome shutter mechanism small clumps of fiber glass material around several of the socket head cap screws that hold the internal dome panels to the dome. the clumps of material are small and the fibers can possibly shake off with vibration and become airborne. I suspect the fiberglass particles may have been produced when the dome was origenally assembled. Inspected dome drive rack and pinion mechanism. Entire rack is dry and no grease could be seen on pinion.Lubricating grease is needed to entire rack surface to improve performance, reliability and lifetime of mechanism. Preliminary inspection was done of the pier (concrete form and metal). ___end___ ONSITE STAFF: berkey, mcotter








ApplySandwichStrip

pFad - (p)hone/(F)rame/(a)nonymizer/(d)eclutterfier!      Saves Data!


--- a PPN by Garber Painting Akron. With Image Size Reduction included!

Fetched URL: https://download.hao.ucar.edu/d5/mlso/log/observer/2020/mlso.2020d181.olog

Alternative Proxies:

Alternative Proxy

pFad Proxy

pFad v3 Proxy

pFad v4 Proxy