[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
[LDM #TKF-950529]: MAV MOS Feed
- Subject: [LDM #TKF-950529]: MAV MOS Feed
- Date: Tue, 23 Sep 2008 17:23:31 -0600
Hi Chad,
re:
> We currently retrieve GFS MOS data via the IDD WMO feed and process it out
> using the following
> lines in our pqact.conf:
> WMO ^FOUS12 .... ([0-3][0-9])([0-2][0-9]) FILE
> /home/ldm/data/GFS_MOS/(\1:yy)(\1:mm)\1\2.FOUS12
> WMO ^FEUS21 .... ([0-3][0-9])([0-2][0-9]) FILE
> /home/ldm/data/GFS_MOS/(\1:yy)(\1:mm)\1\2.FEUS21
> WMO ^FOUS44 .... ([0-3][0-9])([0-2][0-9]) FILE
> /home/ldm/data/GFS_MOS/(\1:yy)(\1:mm)\1\2.FOUS44
>
>
> We would like to do the same for MAV MOS, but have been unable to find the
> appropriate configuration
> entries for pqact.conf to accomplish such.
>
> Any help/advice is greatly appreciated.
Try the following action that is distributed with Unidata GEMPAK:
# MAV - MOS_Aviation_Based_Guidance_From_AVN_Model
WMO ^...... .... ([0-3][0-9])([0-2][0-9])([0-5][0-9]).*/p(MAV)
FILE data/GFS_MOS/(\1:yy)(\1:mm)\1\2.\4
> Chad Shmukler
> Office of the NJ State Climatologist
Cheers,
Tom
****************************************************************************
Unidata User Support UCAR Unidata Program
(303) 497-8642 P.O. Box 3000
address@hidden Boulder, CO 80307
----------------------------------------------------------------------------
Unidata HomePage http://www.unidata.ucar.edu
****************************************************************************
Ticket Details
===================
Ticket ID: TKF-950529
Department: Support IDD
Priority: Normal
Status: Closed