[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

[IDV #WBS-112970]: IDV - mm5 model output in foreign projection



Hi Valentijn-

> Sorry, here is the full support request:
> 
> Now, in displaying the netCDF IDV says under "projections" > "from
> displays" a "none defined". Any suggestions how to solve this, should
> the IDV if properly defined read the projection informastion from the
> netCDF file as it is self-contained?

Have you displayed the data yet?  The "None Defined" would indicate
that you have not yet displayed the data in it's native projection.
This menu is populated by the projections of data that have been
displayed (hence the title "from displays").

Is the Projections->Auto-set Projection menu checked when you try
to display the data?

Another thing to check would be the Data Source properties.  Use
the Data-><data source name>->Edit->Properties menu to look
at the Spatial Subset tab and see if the map shows the area
that you think it should be covering.

Lastly, if the data doesn't display, could you provide a sample
file?

Don Murray

> netcdf
> dods://x6.itc.nl:8080/thredds/dodsC/testRelativeModeloutput/eta_d1.nc {
> dimensions:
> time = 1;   // (has coord.var)
> SIGMAH = 23;   // (has coord.var)
> SCFX = 27;   // (has coord.var)
> YC = 61;   // (has coord.var)
> XC = 40;   // (has coord.var)
> variables:
> char Lambert_Conformal_projection;
> :grid_mapping_name = "lambert_conformal_conic";
> :standard_parallel = 60.0, 30.0; // double
> :longitude_of_central_meridian = 91.75; // double
> :latitude_of_projection_origin = 32.0; // double
> :_CoordinateTransformType = "Projection";
> :_CoordinateAxisTypes = "GeoX GeoY";
> float surface_temperature(time=1, YC=61, XC=40);
> :_CoordinateAxes = "time YC XC ";
> :long_name = "surface_temperature";
> :units = "K";
> :_FillValue = -9999.0f; // float
> :missing_value = -9999.0f; // float
> :coordinates = "lat lon";
> :grid_mapping = "Lambert_Conformal_projection";
> int time(time=1);
> :standard_name = "time";
> :long_name = "time";
> :units = "hours since 2005-6-1 12:00:00.000 +0000";
> :_CoordinateAxisType = "Time";
> float SIGMAH(SIGMAH=23);
> :long_name = "SIGMAH";
> :units = "sigma";
> float SCFX(SCFX=27);
> :long_name = "SCFX";
> :units = "fraction";
> int YC(YC=61);
> :units = "km";
> :long_name = "y coordinate of projection";
> :standard_name = "projection_y_coordinate";
> :_CoordinateAxisType = "GeoY";
> int XC(XC=40);
> :units = "km";
> :long_name = "x coordinate of projection";
> :standard_name = "projection_x_coordinate";
> :_CoordinateAxisType = "GeoX";
> 
> :Conventions = "CF-1.0";
> }
> 
> > -----Original Message-----
> > From: Unidata IDV Support
> > [mailto:address@hidden]
> > Sent: Monday, February 05, 2007 12:16 PM
> > To: Valentijn Venus
> > Subject: [IDV #WBS-112970]: IDV - mm5 model output in foreign
> > projection
> >
> >
> > Valentijn Venus,
> >
> > Your Ticket has been received and a member of our staff will
> > review it and reply accordingly. Listed below are details of
> > this Ticket. Please make sure the Ticket ID remains in the
> > Subject: line in all future correspondence regarding this inquiry.
> >
> >     Ticket ID: WBS-112970
> >     Subject: IDV - mm5 model output in foreign projection
> >     Department: Support IDV
> >     Priority: Normal
> >     Status: Open
> >
> >
> >
> > Please do let us know if we can assist you any further,
> >
> > Unidata User Support
> >
> >
> 
> 


Ticket Details
===================
Ticket ID: WBS-112970
Department: Support IDV