[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

[McIDAS #KFB-284893]: Converting units in satellite data



Hi Carol,

re:
> Is there a way to plot feet instead of meters for the GOES-16 L2 cloud top
> height product? I don't see anything in SU, IMGDISP, or IMGREMAP that
> suggests converting units.

You can create a stretch table that the level as FT instead of M.
It doesn't covert the unit in the calibration, however.

re:
> As a note, meters is what is available via IMGPROBE.

Yup.  What is being returned is the unit suggested/mandated in
the ICD that describes the product.

From the calibration include file (abincalb.inc), the mapping between BRIT and 
CTH [M] is:

    0 -   0
19812 - 255

Given this, the mapping between BRIT and CTH [FT] would be:

    0 -   0
65000 - 255

So, the stretch table should be created using:

SU INI L2-CTH X FT
SU MAKE L2-CTH 0 65000 0 255

List out the stretch table using 'SU TABLE':

SU TABLE L2-CTH
BREAKPOINTS STORED IN TABLE : L2-CTH.ST
INPUT       OUTPUT
-----       ------
 0             0
 65000         255
CALIBRATION TYPE  :
CALIBRATION UNITS : FT
BAND NUMBER       : -1
INTERPOLATION TYPE: LIN
SU: DONE

Notice that I did not specify the 'type' in the 'SU INI name type unit' 
invocation.
This means that the stretch will work with any calibration type.

Please give this a try and let me know if it is what you are looking for.

Cheers,

Tom
--
****************************************************************************
Unidata User Support                                    UCAR Unidata Program
(303) 497-8642                                                 P.O. Box 3000
address@hidden                                   Boulder, CO 80307
----------------------------------------------------------------------------
Unidata HomePage                       http://www.unidata.ucar.edu
****************************************************************************


Ticket Details
===================
Ticket ID: KFB-284893
Department: Support McIDAS
Priority: Normal
Status: Closed
===================
NOTE: All email exchanges with Unidata User Support are recorded in the Unidata 
inquiry tracking system and then made publicly available through the web.  If 
you do not want to have your interactions made available in this way, you must 
let us know in each email you send to us.



pFad - Phonifier reborn

Pfad - The Proxy pFad of © 2024 Garber Painting. All rights reserved.

Note: This service is not intended for secure transactions such as banking, social media, email, or purchasing. Use at your own risk. We assume no liability whatsoever for broken pages.


Alternative Proxies:

Alternative Proxy

pFad Proxy

pFad v3 Proxy

pFad v4 Proxy