Multi-Purpose Test Station - PHADES

PHADES logo
Credit: Brian Maranville

 

Test Station Schematic

PHADES (Polarized 3He and Detector Experiment Station) is typically used for the testing of 3He and related optics, detector optimization, and crystal alignment. A pyrolytic graphite monochromator set at a take-off angle of 75 degrees produces a monochromatic beam of 4.1001(5) \({\unicode{x212B}}\) with fixed energy of 4.8662(6) meV. Flux is relatively low at 2 x 106 \(\frac{n}{cm^2s}\). The vertical divergence of the neutron beam is also small at about 1 degree. The instrument is simply designed, yet highly versatile. It's primary uses are crystal alignment, 3He neutron spin filter testing/development, and detector testing/development.

A series of collimators are available for use. Located at the beam exit, a 25 cm by 75 cm optical table of variable height may be used to support loads up to 100 kg. A second pyrolytic graphite crystal is available for use as an analyzer. Optional removal of the optical table combined with translation of the secondary spectrometer of over 1 m allows large sample environment equipment to be accommodated. Samples are typically mounted on a standard Huber goniometer with ± 22 degree tilt and ± 10 mm translation. Beam to sample heights are 6 inches (152 mm) and 2.75 inches (70 mm) from the Huber base.

A pencil detector (A4) travels from -7 degrees to +150 degrees, providing a maximum Q of 2.96 \({\unicode{x212B}}\)-1 and corresponding minimum sample reflection d-spacing of 2.123 \({\unicode{x212B}}\). Water and air lines are available to support sample environment equipment including electromagnets. Software for hkl crystal alignment is available.

To request time on PHADES please submit a short beam time request through the IMS System. Any questions may be sent to the instrument contacts, listed to the right.

Created February 10, 2020, Updated June 7, 2023








ApplySandwichStrip

pFad - (p)hone/(F)rame/(a)nonymizer/(d)eclutterfier!      Saves Data!


--- a PPN by Garber Painting Akron. With Image Size Reduction included!

Fetched URL: https://www.nist.gov/ncnr/multi-purpose-test-station-phades

Alternative Proxies:

Alternative Proxy

pFad Proxy

pFad v3 Proxy

pFad v4 Proxy