Jump to content

IPWR-900

From Wikipedia, the free encyclopedia
IPWR-900
GenerationGeneration III+ reactor
Reactor conceptpressurized water reactor
Reactor lineIPWR (Indian Pressurized Water Reactor)
Designed byBhabha Atomic Research Centre
Manufactured byNPCIL
StatusUnder development
Main parameters of the reactor core
Fuel (fissile material)235U (LEU)
Fuel stateSolid
Neutron energy spectrumThermal
Primary control methodcontrol rods
Primary moderatorLight Water
Primary coolantLight Water
Reactor usage
Primary useGeneration of electricity
Power (thermal)2700 MWth
Power (electric)900 MWe

The Indian Pressurized Water Reactor-900 (IPWR-900) is a class of pressurized water reactors being designed by the Bhabha Atomic Research Centre (BARC) in partnership with the Nuclear Power Corporation of India Limited to supplement the Indian three-stage nuclear power programme.

History

[edit]

BARC has developed a 83 MW compact light water reactor known as CLWR-B1 for the Indian Navy's Arihant-class submarine program which includes a prototype reactor operating at Kalpakkam since 2002 and was made operational in the INS Arihant in 2013. The experience gained in the naval reactor program is being used to develop a commercial electricity generation reactor of 900 MWe capacity.[1]

To support the industrial capacity to fabricate the large forgings for a reactor pressure vessel, a heavy forge unit has been set up as a joint venture by the Nuclear Power Corporation of India Limited (NPCIL) and Indian engineering conglomerate Larsen & Toubro's subsidiary L&T Special Steels and Heavy Forgings Limited in Hazira, Gujarat. The joint venture has set up a 9000-ton forging press and plans to increase it to 17,000 tons.[2][3] BARC reported the completion of manufacture of test forgings in August 2021 and confirmed the technological know-how and capability to manufacture forgings of thicknesses 350 mm to 750 mm essential to manufacturing of reactor pressure vessels for pressurized water reactor program.[4]

Indian nuclear activities regulator Atomic Energy Regulatory Board carried out the Pre-Consenting design review for the design in the fiscal year 2015–16.[3]

Design

[edit]

The IPWR design is planned to retain commonality of majority of non-nuclear island components of the design with the IPHWR-700 pressurized heavy-water reactors currently in use to limit design timelines and construction costs. The steam generator design and configuration will also be adopted from the IPHWR-700 design.[5]

The IPWR core consists 151 fuel assemblies arranged in a hexagonal pitch with 331 lattice locations wherein 311 locations are occupied by fuel pins, 18 by control guide tubes and 1 by instrumentation tube and the remaining location at centre is occupied by central water rod. The fuel pins have an outer diameter 9.4 mm with a wall thickness of 0.7 mm. The core contains 103 rod cluster assemblies with each cluster containing 18 rods which have B4C and Dy2O3·TiO2 as the control material. The control rods have been designed to provide negative reactivity coefficients with a shutdown margin of 10 mk at hot zero power state for a prolonged time.[6]

IPWR utilises Gadolinium(Gd) compound Gd2O3(Gadolinia) as a neutron absorber for suppression of initial reactivity which is a prominent feature of modern PWR designs including EPR and AP1000. The use of Gd reduces concentration of dissolved boron required at the beginning of the fuel cycle and helps keep the coolant temperature coefficient of reactivity sufficiently negative in all operating conditions.[6]

The reactor will utilise a reactor pressure vessel made of 20MnMoNi55 steel[7] also known as “APURVA” (Advanced Purified Reactor Vessel Alloy).[4] BARC disclosed in January 2020 that a Core catcher design has been validated that can manage a 100% core melt accident.[8][9]

The design will include Generation III+ safety features like Passive Decay Heat Removal System, Emergency Core Cooling System (ECCS), Corium Retention and Core Catcher System.[5]

Reactor fleet

[edit]

The Government of India or NPCIL have not disclosed any locations or timeline for the construction of the first IPWR-900 reactor.

Technical specifications

[edit]
Specifications IPWR-900[6]
Thermal output, MW 2700
Electrical output, MW 900
Efficiency, net % 33.33%
Vapor pressure, in 100 kPa
     in front of the turbine -
     in the first circuit -
Water temperature, °C:  
     core coolant inlet 307.5
     core coolant outlet 320
Equivalent core diameter, m
Active core height, mm 3600
Outer diameter of fuel rods, mm 13.16
Number of fuel rods in assembly 311
Number of fuel assemblies 151
Uranium loading, tons -
Average uranium enrichment, % 4.22
Average fuel burnup, MW · day / kg 30
Maximum fuel burnup, MW · day / kg 50
Average linear heat generation rate in a pin (W/cm) 159.6
Power density (MW/m3 or KW/litre)) 87.4
System pressure (MPa) 15.7
Cycle length (FPDs) 410
Burnable neutron absorber material in fuel (IFBA) Gd2O3(Gadolinia)
Reactivity control Soluble boron (H3BO3 in water)
Control rod material B4C and Dy2O3·TiO2

See also

[edit]

References

[edit]
  1. ^ "BARC begins work on 900 MW pressurised water reactor". Business Standard India. Indo-Asian News Service. 12 August 2013. Retrieved 11 April 2021.
  2. ^ Grover, R.B. (2017). "Opening up of international civil nuclear cooperation with India and related developments". Progress in Nuclear Energy. 101: 160–167. doi:10.1016/j.pnucene.2016.09.016.
  3. ^ a b National report to The Convention on Nuclear safety, Seventh Review Meeting of Contracting Parties, March 2017 (PDF). Atomic Energy Regulatory Board, Government of India. August 2016. p. 2. Retrieved 11 April 2021.
  4. ^ a b Mishra, P.K; Shrivastav, Vivek. "Heavy steel forgings for Pressurised Water Reactor program" (PDF). BARC Newsletter. 377 (July–August 2021): 38. Retrieved 30 August 2021.
  5. ^ a b AB, Mukherjee. "IPWR Indian Pressurized Water Reactor". India Energy Forum (10th Nuclear Conclave).
  6. ^ a b c Raj, Devesh; Kannan, Umasankari (10 March 2020). "Estimation of safety parameters of equilibrium cycle of Indian Pressurized Water Reactor (IPWR)". Life Cycle Reliability and Safety Engineering. 9 (2): 129–134. doi:10.1007/s41872-020-00115-2. S2CID 216161923. Retrieved 11 April 2021.
  7. ^ Annual Report 2018-19, Department of Atomic Energy (PDF). Department of Atomic Energy, Government of India. p. Chapter 1, Page 49. Archived from the original (PDF) on 7 April 2022. Retrieved 11 April 2021.
  8. ^ Mohanty, Ajit Kumar (26 January 2020). "Republic Day address of Director, BARC" (PDF). Bhabha Atomic Research Centre. Retrieved 11 April 2021.
  9. ^ "DAE Annual Report 2016-17" (PDF). Department of Atomic Energy, Government of India: 52. 2017. Archived from the original (PDF) on 2021-04-12. Retrieved 2021-04-12.